Basement finishing projects are notorious for this code violation.
Hot water heater flue pipe clearance.
Note some modern high efficiency water heater may have pvc vents.
Make the vent pipe section between the water heater and the chimney as short and as straight as possible.
Here s an example of what i say.
9 is a typical clearance between a gas fired boiler or furnace flue connector and combustibles.
Home plumbing water heater water heater vent clearance to wood or combustionable materials.
The duct may be metal or plastic depending on the type of vent system.
In an attempt to maximize finished floor space when boxing off the water heater from the rest of the room people often don t leave enough clearance between the new wall framing and the vent pipes.
Single wall vents get very hot requiring a 6 in.
Gas fired heating equipment.
Atmospheric venting refers to a system in which exhaust from the water heater naturally rises out of the appliance s combustion chamber then travels up through a standard chimney style flue.
This construction defect is considered a fire hazard.
For gas fired water heater vents.
An exception is made for non combustible walls such as solid masonry or concrete.
Metal flue fire clearance requirements single wall metal pipe flues gas fired equipment.
All water heater venting systems use a vent duct or pipe also called a chimney or flue to bring exhaust gases from the water heater to the outdoors.
Water heater venting basics.
A single walled vent pipe should be six inches away from any combustible material and a double walled vent pipe should be one inch away.
The minimum distance between the single wall vent pipe and combustible materials is 6 the single wall vent pipe cannot be concealed inside the wall or floor.
6 minimum clearance from single wall vent pipe or flue vent connector to any combustible material.
Single wall vent pipes cannot pass through a ceiling floor firewall or wall.
Metal single wall and double wall.
The water heater vent pipe is too close to combustible material and should be serviced before the close of escrow.
Furnace water heater vent pipe clearance single wall.
A vent pipe is an important part of the gas water heater maintenance don t forget your schedule.
The common rule is that the horizontal part of the single wall vent pipe must be equal or shorter than 75 of it s total developed height.